技術(shù)參數(shù)Technical parameters
用于有功功率的和指示,并具有逆功率、功率繼電器的越限輸出功能。It is used to measure and indicate the active power,and has the over limit output function of the reverse power relay and power relay.
指示精度Accuracy: Class 1.5。
環(huán)境溫度Ambient temperature range:-25℃ to +55℃。
外殼防護(hù)Housing protection:IP44。
耐振動Vibration resistance:2-100HZ≤0.7g。
耐電壓Dielectric test:AC2.6KV,50HZ,1min。
設(shè)置點(diǎn)參數(shù) Set point:(Pn滿度值 Full scale value)
功率越限Power overload:25%~125%×Pn;時間延遲Time delay: 0~20S.
逆功率設(shè)Reverse power : -(0~25%)×Pn;時間延遲Time delay: 0.2~20S.
規(guī)格參數(shù)及測量范圍 Specification parameter and Measuring range:同as F96-W
電源功耗Power:Consumption :≤3VA
輸出觸點(diǎn)容量Contact rating:AC250V ,3A;DC28V,3A.
產(chǎn)品分類 Kind of products
型號 Type | 展開角 angle | 外形尺寸(mm) Outline(AXBXC) | 開孔尺寸 Cut-out(mm) | 結(jié)構(gòu)代碼 Structure code | 外形圖 Outline drawing | 接線圖 Wiring drawing | 重量(Kg) Weight |
F96-WNJB-II,Q96-WTCANA | 90° | 96X96X133 | 92+0.5X92+0.5 | A | 圖Figure 1 | 圖Figure 3 | 0.9 |
F96-WNJ-II,Q96-WTCZANA | 240° | 96X96X133 | 92+0.5X92+0.5 | B | 圖Figure 2 | 圖Figure 3 | 1.1 |
使用說明Directions
使用前應(yīng)檢查儀表接線正確無誤,輸入電壓、電流規(guī)格應(yīng)與銘牌標(biāo)識相符。Before use,the instrument wiring should be checked correctly,and the input voltage and current specifications should be consistent with the nameplate identification.
當(dāng)接通電源后,綠色LED指示燈點(diǎn)亮,表示儀表處于工作狀態(tài)。When power supply is switched on,green LED for indication “power on”is lit,which indicates devise is running correctly.
當(dāng)逆功率或功率超過設(shè)置點(diǎn)時,黃色指示燈(-P>或P>)點(diǎn)亮,再經(jīng)過所設(shè)置的時間延遲,紅色LED燈(RELAY A或B)點(diǎn)亮,表示繼電器已發(fā)生動作而改變狀態(tài)。When the reverse power or power exceeds the set point, the yellow indicator light (-p > or P>) will be on, and after the set time delay, the red LED light (RELAY A or B) will be on, indicating that the RELAY has changed its state due to the action.
特殊用途儀表請?jiān)谛吞柷鞍氩康臄?shù)字后加“J”(僅限于240°儀表),如F96J-WNJ-II。Specify“J”for special meter.(Only for Pointer deflection 240 degree meter)as:F96J-WNJ-II.